- Fuel: Boiler Supplied
- System: Hot Water Generator
- Capacity: up to 4 gpm with 120 MBH boiler
- Efficiency: Up to 100%
The DHWG is a unique way to make domestic hot water using a high efficiency boiler as the heat source. Provides virtually instant domestic hot water from Slant/Fin Lynx and CHS and similar high efficiency boilers with priority control capabilities.
Related products
-
Monitron EH Boiler
- Electric: 240/208v
- 1 & 3 phase
- System: Hot Water
- Sizes: 27 - 137 MBH
- Combustion: Electric
- Capacity: 9 sizes, 8 - 40 KW
- Compatible with any hot water hydronic radiation system
- One piece cast-iron heat exchanger
- Internal baffles improve heat transfer
- Compact, easy to install
- Minimal maintenance
- 25 Year Limited Lifetime Warranty
-
Sentry
- Fuel: Gas
- System: Hot Water
- Natural Draft, Atmospheric
- Capacity: 34-150 MBH
Up to 84.4% AFUE - Intermittent ignition
- Integral draft hood fit sites with clearance as low as 38-1/2"
- Low profile makes problem installations easy
- Advanced natural draft design promises efficiency & reliability
- Includes a reliable, heavy-duty motorized vent damper to maximize efficiency
- Metal push nipples connect individual sections
- 25 Year Limited Lifetime Warranty!
- All Sentry Models DOE 2021 compliant
- S-90 & S-120 Available in Pink -portion of proceeds to support breast cancer charities and support groups
-
The Kicker
- Application: Hot water
- Voltage: 120 VAC, 60 Hz.
- Output: 5075 – 7227 (180 Deg. 1 GPM)
- Range: 140 - 220 Btuh ˚F
- High performance manifold-type heat exchanger
- Two built-in air vent tappings. Coin or screwdriver access.
- Brazed tube joints resist rigors of installation and years of operation
- 1/2" hot water supply and return fittings
- Aluminum turbo fin heat exchanger maximizes heat transfer
- Expanded copper tube bonds fin to copper for high heat transfer
- Heavy duty 2-speed blower motor for extended life. Internally cooled. Permanently lubricated.
- Aluminum squirrel cage blower
- Aquastat permits blower operation only when the water temperature is above 130°F
- Three-position blower switch is easily accessible
- Hot dipped galvanized chassis resists rust and corrosion
- Rubber grommets cushion chassis for quiet operation
- 22" matte black grille
-
CHS Series
- Type: Gas-Fired Hot Water
- Construction: Stainless Steel Heat Exchanger
- Capacity: 85 - 399 Btuh
- 95% AFUE
- Stainless Steel Heat Exchanger
- Up to 5:1 Modulation ratio
- 85,000 to 399,000 single boiler Btuh input
- Natural gas or propane
- PVC, CPVC, polypropylene or stainless steel air intake and vent pipe—up to 100 ft equivalent length
- Quiet operation
- Environmentally friendly - Low NOx
- Built-in digital control board with outdoor reset-
- Warranty
- All CHS models are 2021 DOE compliant
- Fuel: Boiler Supplied
- System: Hot Water Generator
- Capacity: Up to 4 gpm with 120 MBH boiler
- Efficiency: Up to 100%
- Hot water when you need it
- Ideal for small residences
- Heat transfer from boiler to DHW with nearly 100% efficiency
- Maintenance-free brazed plate stainless steel heat exchanger
- Wall Hung, light weight, easy to install
- Reversible - mounts with piping facing left or right
- Taco - 0011 circulator with integral flow check
- Flow switch included
Incorporating a brazed plate stainless steel heat exchanger, boiler water flows between half the plates transferring heat to domestic water on the other side of the plates. The hot water [production is limited primarily by the boilers BTUH output. This remarkable unit transfers heat to the domestic hot water with nearly 100 percent efficiency. As soon as there is minimal flow of domestic hot water, the flow switch activates both the boiler and the circulator and within seconds hot water is available for domestic purposes. It requires no maintenance or cleaning and will last for years and years. A circulator pump and flow switch are included. The pump is sized to overcome the friction losses of the boiler and the heat exchanger and therefore provides enough boiler water flow to transfer the maximum amount of heat energy from the boiler to the domestic hot water.